Frete Grátis
  • Google Plus

Iddq Testing Of VLSI Circuits (Cód: 6327168)

Ravi K. Gulati; Charles F. Hawkins

SPRINGER VERLAG POD

Ooopss! Este produto está temporariamente indisponível.
Mas não se preocupe, nós avisamos quando ele chegar.

Ooops! Este produto não está mais a venda.
Mas não se preocupe, temos uma versão atualizada para você.

Ooopss! Este produto está fora de linha, mas temos outras opções para você.
Veja nossas sugestões abaixo!

R$ 1.048,80 em até 10x de R$ 104,88 sem juros
Cartão Saraiva R$ 996,36 (-5%) em até 1x no cartão ou em até 12x de R$ 87,40 sem juros
Grátis

Cartão Saraiva

Descrição

Power supply current monitoring to detect CMOS IC defects during production testing quietly laid down its roots in the mid-1970s. Both Sandia Labs and RCA in the United States and Philips Labs in the Netherlands
practiced this procedure on their CMOS ICs. At that time, this practice stemmed simply from an intuitive sense that CMOS ICs showing abnormal quiescent power supply current (IDDQ) contained defects.
Later, this intuition was supported by data and analysis in the 1980s by Levi (RACD, Malaiya and Su (SUNY-Binghamton), Soden and Hawkins (Sandia Labs and the University of New Mexico), Jacomino and co-workers (Laboratoire
d'Automatique de Grenoble), and Maly and co-workers (Carnegie Mellon University). Interest in IDDQ testing has advanced beyond the data reported in the 1980s and is now focused on applications and
evaluations involving larger volumes of ICs that improve quality beyond what can be achieved by previous conventional means. In the conventional style of testing one attempts to propagate the logic states of the suspended
nodes to primary outputs. This is done for all or most nodes of the circuit. For sequential circuits, in particular, the complexity of finding suitable tests is very high. In comparison, the IDDQ test
does not observe the logic states, but measures the integrated current that leaks through all gates. In other words, it is like measuring a patient's temperature to determine the state of health. Despite perceived
advantages, during the years that followed its initial announcements, skepticism about the practicality of IDDQ testing prevailed. The idea, however, provided a great opportunity to researchers. New
results on test generation, fault simulation, design for testability, built-in self-test, and diagnosis for this style of testing have since been reported. After a decade of research, we are definitely closer to practice.

Características

Produto sob encomenda Sim
Marca SPRINGER VERLAG POD
Cód. Barras 9780792393153
Altura 25.40 cm
I.S.B.N. 9780792393153
Profundidade 0.95 cm
Referência 9780792393153
Ano da edição 1992
Idioma Inglês
Número de Páginas 132
Peso 0.45 Kg
Largura 17.80 cm
AutorRavi K. Gulati; Charles F. Hawkins

Avaliações

Avaliação geral: 0

Você está revisando: Iddq Testing Of VLSI Circuits